panel 1

Thermal panels of polyurethane coating.

It consists of two steel sheets and polyurethane foam core. The coating panels are characterized by easy and fast installation while providing high thermal insulation and waterproofing. Most panels are made of galvanized and prepainted steel sheets, but can also be created from aluminum sheet and stainless steel.

Applications

Roofs of metal buildings, parking lots, canopies, prefabricated houses, sports facilities, stables.

Dimensions – Weight

Working width 100cm

Length 50cm to 16m

Panel thickness mm 30 40 50 60 80 100
Total height mm

72

82

92

102

122

142

Weight kg/m2 (steel sheet 0,50mm)

10.9

11.3

11.7

12.15

13.0

13.85

Weight kg/m2 (aluminum sheet 0,50mm) 4,80 5,25 5,65 6,10 6,90 7,75

Color cards

RAL 1015

BEIGE

RAL 2004

ORANGE

RAL 1023

YELLOW

RAL 3013

TILE RED

RAL 3020

RED

RAL 5010

DARK BLUE

RAL 5024

PALE BLUE

RAL 6005

DARK GREEN

RAL 6021

PALE GREEN

RAL 7015

DARK GREY

RAL 7040

PALE GREY

RAL 9002

ICE WHITE

RAL 9006

GREY

RAL 9007

GREY

RAL 9010

WHITE

Support – Waterproofing

A range of binders, available from us ( self-tapping screws , washers ), is necessary for the proper installation of roof panels . There are also special sealing materials for roofs with a little slope for structures exposed to very humid environment ( butylate string , foam wads) . We recommend using screws 2.4 per m2. A number of special items related to waterproofing and aesthetic completion of the coating is also available. The specificity of each construction requires contact with our company in order to tailor the specific pieces in your construction.

Performance

Soundproofing:

All roof panels have a single insulation weighted value Rw = 25 dB.

Thermal Insulation:

Panel Thickness mm Thermal Conductivity (k) in W/m2K

30

0,70

40

0,53

50

0,42

60

0,35

80

0,26

100

0,21

 
 
 

The response of the panel to fire with a common polyurethane foam is B3. There is also the possibility of using polyurethane foam PIR with extra endurance in case of fire.

. The lateral coating system is produced from environmentally friendly materials (CFC free), characterized as ecological and not considered harmful.